GKC-F High Voltage Switch Dynamic Characteristic Tester Uses * Measure the volt-ampere characteristics of linear resistive elements;  

* Measure the forward and reverse volt-ampere characteristics of ordinary diodes;  

* Measure the forward and reverse volt-ampere characteristics of Zener diodes;  

* Measure the volt-ampere characteristics of small bulbs.  

Technical Parameters and Features  

* DC regulated power supply: Two ranges available, 2V and 20V, continuously adjustable, with three-and-a-half digit digital display;  

* Voltage display: Range 0~200V, three-and-a-half digit digital display;  

* Current display: Four ranges available, 200uA, 2mA, 20mA, 200mA, with three-and-a-half digit digital display;  

* All use national standard connectors for manual circuit connection, which can cultivate hands-on ability.



GKC-F High Voltage Switch Dynamic Characteristic Tester Also known as:

High voltage switch dynamic characteristic tester, switch mechanical characteristic tester, high voltage switch comprehensive tester, circuit breaker dynamic characteristic tester, circuit breaker mechanical characteristic tester, circuit breaker comprehensive tester, high voltage switch time characteristic tester, high voltage switch characteristic tester, switch characteristic tester, circuit breaker tester, switch mechanical characteristic tester,



Main Uses:  Suitable for mechanical characteristic testing of high voltage circuit breakers from various domestic and imported manufacturers, including oil-immersed (multi-oil and low-oil), SF6, vacuum, etc. Also suitable for time testing of electromagnetic action electrical appliances (such as contactors, relays, etc.).



Main Features:  The instrument has a built-in DC operating power supply, and can flexibly use an external operating power supply or external synchronous trigger. Large screen LCD display, with preset typical switch speed definitions; can switch time waveform diagram to display 1 channel of close/open command, 12 channels of time jumps; S-T graph displays close/open motion curves, and can dynamically analyze and calculate; V-S curve intuitively observes motion speed; I-T curve observes the action process of the electromagnet. Microcomputer printer prints data for retention. The instrument can save 255 test records, and can communicate with a computer. The data management software can analyze, correct, and print out test reports. The accessory box is equipped with sensors such as 0.1mm, 1mm linear, 1-degree angle photoelectric auxiliary contacts, and a full set of accessories including test wires and speed measurement mounting brackets.