Purpose of High Voltage Switch Mechanical Characteristics Tester
Widely applicable for DC high voltage testing of electrical equipment such as zinc oxide arresters, magnetic blow arresters, power cables, generators, transformers, circuit breakers, etc.
Operating steps for the High Voltage Switch Mechanical Characteristics Tester:
1. Use wires to securely connect the grounding screw of the generator and the grounding terminal of the test object to the earth ground wire.
2. Take out the nylon extension rod, wipe it clean, screw it together with the spherical high-voltage ammeter, and insert it into the high-voltage output bushing.
3. Insert the plug of the spare shielded cable into the spherical ammeter (at this time, the meter shows 000), and connect the other end to the test object. (Note: The outer sheath of this cable carries high voltage and must be insulated from ground.)
4. Insert the five-pin plug of the high-voltage generator cable into the control box and tighten it, then plug in the control box power cord. Turn the voltage adjustment knob counterclockwise to zero. After pressing the start switch, you can adjust and increase the voltage as needed. (This machine is equipped with zero-position interlock and grounding protection. It cannot be started if the voltage adjustment knob is not returned to zero, nor if the ground wire is not properly connected.)
5. After testing, turn off the machine. When the high voltage automatically drops to near zero (the machine is equipped with an automatic discharge resistor for currents greater than 200uA), use a discharge rod to discharge the test object, then unplug the power plug before disconnecting wires.
Product Features
1. Small size, light weight, more aesthetically pleasing, more reliable, easy to operate, and fully functional; it is an ideal replacement product for the new century.
2. Utilizes advanced technology and manufacturing processes, with pulse train logic array modulation, high-power IGBT devices, and phase fuzzy control, resulting in higher output stability and smaller ripple coefficient.
3. High precision and accurate measurement. The output voltage adjustment uses a single multi-turn potentiometer, ensuring smooth voltage increase, high adjustment precision, and coarse and fine adjustment functions. The instrument can measure leakage current at both high and low voltage ends. The high-voltage end uses a spherical shielded digital display, which is resistant to discharge shocks and has good anti-interference performance, suitable for field use.
4. The voltmeter on the control box directly displays the voltage applied to the load test object, eliminating the need for an external voltage divider and current limiting resistor, simplifying wiring and operation.
5. Negative polarity output, zero-start, continuously adjustable, with various protection functions such as overvoltage, overcurrent, return-to-zero, grounding protection, and disconnection protection. Strong automatic protection, safe operation, and all technical indicators are superior to industry standards and similar products.