Lightning Protection Component Tester



Accuracy:   Cx:     ±(Reading×1%+1pF)

tgδ: ±(Reading×1%+0.00040)

Anti-interference Index: Frequency conversion anti-interference, can still achieve the above accuracy under 200% interference

Capacitance Range: Internal applied high voltage: 3pF~60000pF/10kV    60pF~1μF/0.5kV

External applied high voltage: 3pF~0.5μF/10kV     60pF~10μF/0.5kV

Resolution:           Up to 0.001pF, 4 significant digits

tgδ Range:    Unlimited, resolution 0.001%, automatic identification of three types of test objects: capacitor, inductor, resistor.

Test Current Range: 10μA~1A

Internal Applied High Voltage: Set voltage range: 0.5~10kV   Voltage resolution: 1V    Accuracy: 2%

Maximum Output Current: 200mA

Voltage Regulation Method: Continuous smooth adjustment

Test Frequency: 45, 50, 55, 60, 65Hz single frequency

45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion

Frequency Accuracy: ±0.01Hz

External Applied High Voltage: Maximum test current 1A for normal wiring, power frequency or variable frequency 40-70Hz

Maximum test current 10kV/1A for reverse wiring, power frequency or variable frequency 40-70Hz

CVT Self-Excitation Method Low Voltage Output: Output voltage 3~50V, output current 3~30A

Measurement Time: Approximately 36s, depending on measurement method

Input Power: 180V~270VAC, 50Hz±1%, powered by mains or generator

Computer Interface: Standard RS232 interface

Printer:      Weihuang A7 thermal micro printer

Ambient Temperature: -10℃~50℃

Relative Humidity: <90%

Dimensions: 460×360×350mm

Instrument Weight: 28kg



35kV Variable Frequency Dielectric Loss Tester - Level 4 Contractor Equipment List Technical Parameters:



High Voltage Output: 0.5~10kV, each step increases by 500V, total ten steps, Capacity: 1000VA

Accuracy: tgδ: ±(Reading*1.0%+0.08%)

Cx: ±(Reading*1.5%+5PF)

Resolution: tgδ: 0.01% Cx: 1pF

Measurement Range:

0.1% < tgδ < 50%

3PF< Cx < 60000PF

At 10KV, Cx≤30000PF 

At 5KV, Cx≤60000PF

Power Supply Harmonic Adaptation Capability: ≤3%



Introduction:



One operation, the microcomputer automatically completes the entire measurement process. It is a dielectric loss measurement device. The variable frequency anti-interference dielectric loss tester can also



Safety Measures:



1. Before using this instrument, be sure to read this manual carefully.



2. The operator should have general knowledge of electrical equipment or instruments.



3. The instrument should avoid severe vibration.



4. The instrument must be reliably grounded to prevent electric shock hazards.



5. After the test, press the reset button, turn off the power switch, and strictly prohibit disassembling test cables or replacing oil samples while energized.



6. Daily maintenance of the instrument must be carried out without power supply, otherwise high voltage danger