Product Configuration Instructions: 1. Users can optionally configure compensation capacitors.
2. Special test objects can be customized.
Common Models
0-44/22, capacity 44KVA, voltage 22KV
I. Cable AC Withstand Voltage Test Series
| Model | Test Items Satisfied | Reactor Configuration | Remarks |
| DFVF3000-44/22 | 10kV (300mm) cable 1KM | 22kV x 1 unit | Portable |
| DFVF3000-132/66 | 1. 10kV (300mm) cable 3KM 2. 35kV (300mm) cable 1KM |
22kV x 3 units | Portable |
| DFVF3000-264/52 | 1. 10kV (300mm) cable 5KM 2. 35kV (300mm) cable 2KM 3. 35kV transformers, switches, 4. 10kV motors, transformers 5. Generators up to 600MW, etc. |
22kV x 6 units | Portable |
| DFVF3000-1560/66 | 110kV (300mm) cable 3KM | 130kV x 2 units | Non-portable |
II. Generator Power Frequency Withstand Voltage Test Series
| Model | Test Items Satisfied | Reactor Configuration | Remarks |
| DFVF3000-44/22 | 1. Generators up to 100MW, phase capacitance 0.1-0.3uF 2. 10kV (300mm) cable 1KM |
22kV x 1 unit | Portable |
| DFVF3000-100/36 | 1. Generators up to 600MW, phase capacitance 0.1-0.25uF 2. 10kV (300mm) cable 1.5KM |
18kV x 2 units | Portable |
| DFVF3000-176/44 | 1. Generators up to 600MW, phase capacitance 0.1-0.3uF 2. 10kV (300mm) cable 3KM 3. Can also cover generator busbars, main transformers, etc. |
22kV x 4 units | Portable |
III. GIS and SF6 Switch AC Withstand Voltage Test Series
| Model | Test Items Satisfied | Reactor Configuration | Remarks |
| DFVF3000-250/200 | 1. AC withstand voltage test for 110kV GIS 2. 35kV (300mm) cable 1KM 3. 10kV (300mm) cable 3KM 4. Power frequency withstand voltage for transformers below 220kV 5. AC withstand voltage for 110kV instrument transformers |
40kV x 5 units | Portable |
| DFVF3000-100/200 | 1. AC withstand voltage test for 110kV GIS 2. AC withstand voltage for 110kV instrument transformers | 50kV x 4 units | Portable |
IV. Power Frequency AC Withstand Voltage Test Series for Transformers, Motors, etc.
| Model | Test Items Satisfied | Reactor Configuration | Remarks |
| DFVF3000-105/84 | 1. Power frequency withstand voltage test for 110kV transformers 2. Power frequency withstand voltage test for 10kV motors 3. AC withstand voltage test for 35kV switches 4. 10kV (300mm) cable 1KM |
28kV x 3 units | Portable |
| DFVF3000-100/80 | 1. Power frequency withstand voltage test for 110kV transformers 2. Power frequency withstand voltage test for 10kV motors 3. AC withstand voltage test for 35kV switches 4. 10kV (300mm) cable 1KM |
40kV x 2 units | Portable |
(Note: The above only lists some common models; customization is available upon request.)