Automatic 500L Capacitance and Inductance Tester Product Application:



It is specially developed under the guidance of the expert working group for reactive power compensation devices, targeting the problems existing in measuring the capacitance value of individual capacitors in shunt capacitor banks at substation sites. It focuses on solving the following problems:



(1) On-site measurement of individual capacitors requires removing connecting wires, which not only involves heavy workload but also easily damages the capacitors;



(2) The low output voltage of capacitance meters leads to low fault detection rate.



(3) Measuring the inductance of reactors. This instrument features low measurement workload, quick and simple operation, stable performance, accurate measurement, and high fault detection rate.



In addition, its current measurement unit can also be used for measuring electrical equipment such as CVTs and arresters, providing multi-functionality in one instrument.



Automatic 500L Capacitance and Inductance Tester Precautions:



1. Test voltage: If the impedance of the test object is unknown, you can first test with 2V. If the test current is less than 1A, you can switch to 30V for measurement.



2. Current detection: Clamp the CT around the part where current needs to be measured. For example, it can be clamped onto the lead wire connecting the capacitor, not necessarily the capacitor bushing. If measuring total current, it can also be clamped directly onto the voltage lead.



3. Clamp CT orientation: It is required that the front face of the current clamp faces the red clip (i.e., 2V or 20V) direction. At this time, the instrument automatically distinguishes between capacitance, inductance, or resistance.



4. Magnetic field interference: It is recommended to keep the clamp CT more than 1 meter away from the instrument. If measuring an inductor with severe magnetic flux leakage, it is recommended to keep more than 1 meter away from the inductor.



Product Parameters









































Capacitance Range 0.1μF~2,500μF
Capacity Range 5~20,000 kvar
Measurement Accuracy 0.2μF ~ 2500μF  ±1% reading ±0.05μF
Inductance Range 1mH ~ 50H ; Measurement Accuracy: ±3% reading ±2 digits
Output Measurement Voltage AC 26V/500VA; 50Hz
Display Mode Large screen LCD with full Chinese output, TPμp-40 panel-type thermal printer
Dimensions/Weight 370×370×220 mm / 16 kg
Working Conditions Ambient temperature: 0℃ ~ +40℃, relative humidity: ≤90%
Power supply: AC 220V±10%; 50Hz


Technical Specifications:



1. Capacitance Measurement



Measurement Range:  0.2μF~2200μF (basic range 2μF~2200μF)



Accuracy:   ±(reading×1.5%+0.02μF)       



Minimum Resolution: 0.001μF (4-digit display)



2. Inductance Measurement



Measurement Range:  0.2mH~50H (basic range 2mH-10H)



Accuracy:    ±(reading×2%+2 digits)



  Minimum Resolution: 0.001mH (4-digit display)



3. Resistance Measurement



Measurement Range:  0.1Ω~12.5kΩ (basic range 0.1Ω~1kΩ)



Accuracy:    ±(reading×1%+2 digits)



  Minimum Resolution: 0.001Ω (4-digit display)



4. Current Measurement



Measurement Range: 0~200mA~2A~20A (basic range 200mA~20A)



Accuracy:  ±(reading×1%+2 digits)