It has functions such as memory, calculation, hold, self-check, and leakage alarm. It has high-voltage short-circuit protection, overcurrent protection, high-voltage preset, and other functions. The high-voltage self-discharge time is less than 5 seconds. The test results are displayed by two 3 1/2 LCD digital displays, one showing the voltage value and the other showing the current value, with high accuracy and good reliability. It can be used as an adjustable DC high-voltage source (1kV~10kV) with output current ≤1mA.
Technical Parameters
Withstand voltage: AC 2.3kV 50Hz 1min
Operating temperature and humidity: 0℃~+40℃ <90%RH
Storage temperature and humidity: -10℃~+50℃ <90%RH
Power supply: AC220V±10% 50Hz
Power consumption: <40W
Dimensions: 280mm(L)×280mm(W)×90mm(D)
Weight: ≤4 kg
Main features of the lightning protection element tester:
(1) Suitable for testing DC parameters of overvoltage protection components such as zinc oxide arresters (varistors), metal-ceramic two-electrode and three-electrode discharge tubes, and vacuum lightning arresters.
(2) Has functions such as high-voltage short-circuit protection, overcurrent protection, high-voltage preset, and range adjustment.
(3) Has self-check and discrimination function, which can issue an audible alarm for over-range tests during measurement.
(4) Has memory, calculation, hold, control, and continuous testing functions.
(5) Test results are displayed by 3 1/2 digit LCD digital display, which can automatically display accurate and reliable required data.
Technical indicators of the lightning protection element tester:
(1) Varistor measurement
| Technical Indicators | Measurement Range | Working Error | Test Conditions |
| Initial action voltage U1mA | 0~1999V | ≤±1%±1d | 1mA±5μA |
| Leakage current I0.75U1mA | 0~199.9μA | ≤±2μA±1d | 0.75U1mA ≤±1%±1d |
(2) Discharge tube measurement
| Technical Indicators | Measurement Range | Working Error | Test Conditions |
| DC breakdown voltage Vsdc | 8~1999V | ≤±1%±1d | Voltage rise rate 100V/S±10% |
(3) Other indicators
Insulation resistance: ≥10MΩ (500V)
Withstand voltage: AC 2kV 50HZ 1min
Operating temperature and humidity: -5℃~+40℃ ≤85%RH
Storage temperature and humidity: -10℃~+50℃ ≤85%RH
Power supply: AC 110V/220V 50Hz/60Hz
DC 12V 0.5A
Power consumption: 10W