Lightning Protection Element Tester



Transformation ratio measurement accuracy: ±reading×1% Transformation ratio measurement range: 10~99999



Phase measurement accuracy: ±0.1° Phase measurement range: 0~359.9°



Measurement time: approximately 40s, depending on the measurement method



Input power: 180V~270VAC, 50Hz±1%, mains or generator supply



Computer interface: standard RS232 interface



Printer: Weihuang A7 thermal micro printer



Ambient temperature: -10℃~50℃



Relative humidity: <90%



Dimensions: 460×360×350mm



Instrument weight: 28kg



Applications:



The instrument is also suitable for measuring tgδ and capacitance of high-voltage electrical equipment in workshops, laboratories, and scientific research institutions; it has advantages of convenience, simplicity, and accuracy for insulation oil loss testing.

The dielectric loss measuring instrument can measure high-voltage electrical equipment that is ungrounded or directly grounded using positive and reverse wiring methods.

The dielectric loss measuring instrument is internally equipped with a high-voltage step-up transformer and incorporates safety protection measures such as zero-crossing closing and lightning protection. During the test, it outputs high voltages of different levels from 0.5kV to 10kV, making operation simple and safe.