3.2 Current Transformer Measurement Range:



Transformation ratio: 5A/5A~25000A/5A (5A/1A~5000A/1A).



Turn ratio error: 1%.



3.3Voltage Transformer Measurement Range:



2.2kV~132kV, measurement error: ratio error class 0.5.



3.4 Actual Secondary Burden Measurement



Burden 10VA~500VA, measurement error: class 2



CT burden 0.1Ω~25Ω, measurement error: class 2



3.5-inch Operating Conditions:



Power supply voltage: AC 220V ±10%



Power supply frequency: 50Hz ±2%



Ambient temperature: (0~40)℃



Ambient humidity: <85% at 25℃



Technical Specifications:



    1. Input voltage: AC 220V or 380V, 50Hz, automatic identification of input voltage.

    2. Operating ambient temperature: 0~40℃

    3. Output voltage:

        When input AC 220V, output 0~550V;

        When input AC 380V, output 0~1000V.

Current: maximum instantaneous current is 240A when measuring transformation ratio

      and 15A when testing volt-ampere characteristics.

    4. Digital voltmeter measurement range: 0~999.9V; resolution: 0.1V.

                          When used as current display: 0~999.9mA; resolution: 0.1mA.

    5. Digital ammeter measurement range: 0~15A (240A), resolution: 0.01A.

    6. Error: I≤3%, U≤3%.

    7. When measuring CT transformation ratio, the ratio value can be automatically calculated, and the data and calculation results can be printed.

    8. When testing volt-ampere characteristics, store and print 20 sets of current and voltage values and the volt-ampere characteristic curve.

    9. Dimensions: length × width × height = 470 × 340 × 260 mm³

   10. Weight: 21kg.