The fully automatic capacitance and inductance tester adopts synchronous sampling technology for standard capacitors and tested capacitors, which is not affected by power supply voltage fluctuations. In addition, the measurement process is fully automatic, avoiding errors caused by manual operation, thus featuring good stability, repeatability, accuracy, and reliability.



1. Capacitance range: 0.2μF to 2,000μF;

Capacity range: 5 to 20,000 kvar;

Measurement accuracy: ±1.5%×reading ±2 digits;

Resolution: ±1.0%rdg;

2. Inductance range: 1mH to 9.99H; Measurement accuracy: ±1.5%±2 digits

3. Output measurement voltage: AC 26V/500VA; 50Hz;

4. Display mode: large-screen LCD with full Chinese output, TPμp-40 panel-type thermal printer

5. Dimensions and weight: 370×370×220 mm / 8 kg

6. Working conditions:

Ambient temperature: 0℃ to +40℃, relative humidity: ≤90%

Power supply: AC 220V±10%; 50Hz;

Measurement range, resolution, and error values



























Capacitance measurement gear: Error value:
0.020μF to 0.200μF ±0.5%
0.200μF to 2.000μF ±0.5%
2.000μF to 20.00μF ±0.5%
20.00μF to 200.0μF ±0.5%
200.0μF to 2000.μF ±0.5%





























Capacitor reactive power 0 to 20.00Mvar Error value ±1%
Capacitor active power 0 to 20.00kW Error value ±1%
Capacitor dissipation factor 0 to 20.00% Error value ±1%
Capacitor resistance component 0 to 10.00MΩ Error value ±1%

























Inductance measurement gear Error value
0.10mH to 0.200H ±0.5%
2.000H to 20.00H ±0.5%
20.00H to 200.0H ±0.5%
200.0H to 2000.H ±0.5%





























Inductor reactive power 0 to 20.00Mvar Error value ±1%
Inductor active power 0 to 20.00kW Error value ±1%
Inductor dissipation factor 0 to 20.00% Error value ±1%
Inductor resistance component 0 to 10.00MΩ Error value ±1%