Technical Indicators of Lightning Protection Element Tester:



(1) Varistor Measurement

























Technical Indicators



Measurement Range



Working Error



Test Conditions



Initial Action Voltage U1mA



0~1999V



≤±1%±1d



1mA±5μA



Leakage Current I0.75U1mA



0~199.9μA



≤±2μA±1d



0.75U1mA



≤±1%±1d




(2) Discharge Tube Measurement



















Technical Indicators



Measurement Range



Working Error



Test Conditions



DC Breakdown Voltage Vsdc



8~1999V



≤±1%±1d



Voltage Rise Rate



100V/S±10%




(3) Other Indicators



Insulation Resistance: ≥10MΩ(500V)



Withstand Voltage: AC 2kV 50HZ 1min



Operating Temperature and Humidity: -5℃~+40℃ ≤85%RH



Storage Temperature and Humidity: -10℃~+50℃ ≤85%RH



Power Supply: AC 110V/220V 50Hz/60Hz



DC 12V 0.5A



Power Consumption: 10W