Technical Specifications

1. Instrument Measurement Range and Accuracy:



1) Capacitance Measurement



a. Capacitance Measurement Range: 0.1μF to 3,300μF



b. Reactive Power Measurement Range: 5 to 20,000 kvar



c. Measurement Accuracy: ±(1.0% reading + 0.02μF)



d. Resolution: 0.001μF        



2) Current Measurement



a. Current Measurement Range: 0 to 199.9 mA; 0 to 1.999 A; 0 to 19.99 A; 0 to 199.9 A; 0 to 1000 A



b. Measurement Accuracy: ±(3.0% reading + 0.05 A)



c. Resolution: 0.01 A



3) Inductance Measurement



a. Inductance Measurement Range: Small inductance mode: 0.1 mH to 5 mH



                 Large inductance mode: 5 mH to 50 H



b. Inductive Reactance Measurement Range: 50 mΩ to 20 kΩ



c. Measurement Accuracy: ±(3.0% reading + 0.05 mH)



d. Resolution: 0.01 mH



4) Resistance Measurement Range:



a. Resistance Measurement Range: Small resistance mode: 50 mΩ to 1 Ω                  



                 Large resistance mode: 1 Ω to 20 kΩ



b. Measurement Accuracy: ±(3.0% reading + 0.05 Ω)



c. Resolution: 0.01 Ω



2. Power Supply



1) Rated Voltage: 220V AC ±10%



2) Rated Frequency: 50 Hz



3) Rated Output: 2V/20V/500VA



3. Operating Conditions:



1) Ambient Temperature: -10°C to +50°C



2) Relative Humidity: ≤90%



4. Printing Method: LCD display with full Chinese characters



             Panel-mounted high-speed printer



5. Dimensions and Weight: 370×260×220 mm / 12 kg