Product Features

1. The reactors of the same voltage level and capacity are smaller in size and lighter in weight; the temperature rise is small under rated load; they are dry-type epoxy cast, with high mechanical strength, good electrical insulation performance, beautiful and reliable 

2. The variable frequency power supply control box has large capacity margin; strong protection functions; good output waveform; good stability; multiple working modes, easy operation; compatible with single-phase 220V or three-phase 380V input power, convenient for on-site power supply

3. Flexible configuration. Different types of reactors can be selected to meet different test requirements, achieving multiple uses with one machine, high cost performance

Technical Indicators:









































Rated Output Voltage 0~1000kV and below
Output Frequency 30~300Hz
Resonant Voltage Waveform Pure sine wave, waveform distortion rate ≤1.0%
Duty Cycle Continuous operation at full power for 60 minutes
Quality Factor 30~90
Frequency Adjustment Sensitivity 0.1Hz
Instability <0.05%
Working Power Supply Single-phase 220V or three-phase 380V±10%
Power frequency 50Hz±5%


Series Product Configuration and Applicable Scope: 

































































Product Model and Name Applicable Scope (AC withstand voltage test equipment for electrical equipment in substations with voltage levels of 10kV~500kV, frequency 30~300Hz)
Variable Frequency Source Resonant Reactor Excitation Transformer Voltage Divider Applicable Scope
BPXZ-50/50/25 3kW 25kV/1A two units

(dry-type)
3kVA

(dry-type)
50kV  10kV power transformers of 1000kVA and below

 10kV switches, busbars, PT, CT, etc.

 10kV (300mm2) cables ≤1.0km
BPXZ-108/108/27 5kW 27kV/1A four units

(dry-type)
5kVA

(dry-type)
110kV  35kV power transformers of 31500kVA and below

 35kV switches, busbars, PT, CT, etc.

 10kV (300mm2) cables 2km

 35kV (300mm2) cables 0.5km
BPXZ-200/200/50 10kW 50kV/1A four units

(dry-type)
10kVA

(dry-type)
200kV  110kV power transformers of 50000kVA and below

 110kV GIS, PT, CT, etc. (preventive test)

 35kV (300mm2) cables ≤1.0km

 10kV (300mm2) cables ≤2.0km
BPXZ-270/270/45 15kW 45kV/1A six units

(dry-type)
15kVA

(dry-type)
300kV  110kV power transformers of 50000kVA and below

 110kV GIS, PT, CT, etc.

 35kV (300mm2) cables ≤1.2km

 10kV (300mm2) cables ≤3.0km
BPXZ-800/400/50 30kW 50kV/2A eight units

(dry-type)

100kV/2A four units

(oil-immersed)
30kVA

(dry-type)

30kVA

(oil-immersed)
400kV  220kV power transformers of 80000kVA and below

 110kV power transformers of 50000kVA and below

 110kV/220kV GIS, PT, CT, etc.

 35kV (300mm2) cables ≤2.0km

 110kV (300mm2) cables ≤0.7km
BPXZ-1600/800/200 60kW 200kV/2A four units

(oil-immersed)
60kVA

(dry-type)
800kV  220kV power transformers of 80000kVA and below

 110kV power transformers of 50000kVA and below

 500kV GIS, PT, CT, etc.

 220kV switches, GIS, PT, CT, etc.

 110kV (400mm2) cables ≤1.5km

 220kV (400mm2) cables ≤1.0km