Product Features
1. The reactors of the same voltage level and capacity are smaller in size and lighter in weight; the temperature rise is small under rated load; they are dry-type epoxy cast, with high mechanical strength, good electrical insulation performance, beautiful and reliable
2. The variable frequency power supply control box has large capacity margin; strong protection functions; good output waveform; good stability; multiple working modes, easy operation; compatible with single-phase 220V or three-phase 380V input power, convenient for on-site power supply
3. Flexible configuration. Different types of reactors can be selected to meet different test requirements, achieving multiple uses with one machine, high cost performance
Technical Indicators:
| Rated Output Voltage | 0~1000kV and below |
| Output Frequency | 30~300Hz |
| Resonant Voltage Waveform | Pure sine wave, waveform distortion rate ≤1.0% |
| Duty Cycle | Continuous operation at full power for 60 minutes |
| Quality Factor | 30~90 |
| Frequency Adjustment Sensitivity | 0.1Hz |
| Instability | <0.05% |
| Working Power Supply | Single-phase 220V or three-phase 380V±10% |
| Power frequency 50Hz±5% |
Series Product Configuration and Applicable Scope:
| Product Model and Name | Applicable Scope (AC withstand voltage test equipment for electrical equipment in substations with voltage levels of 10kV~500kV, frequency 30~300Hz) | ||||
| Variable Frequency Source | Resonant Reactor | Excitation Transformer | Voltage Divider | Applicable Scope | |
| BPXZ-50/50/25 | 3kW | 25kV/1A two units (dry-type) |
3kVA (dry-type) |
50kV | 10kV power transformers of 1000kVA and below 10kV switches, busbars, PT, CT, etc. 10kV (300mm2) cables ≤1.0km |
| BPXZ-108/108/27 | 5kW | 27kV/1A four units (dry-type) |
5kVA (dry-type) |
110kV | 35kV power transformers of 31500kVA and below 35kV switches, busbars, PT, CT, etc. 10kV (300mm2) cables 2km 35kV (300mm2) cables 0.5km |
| BPXZ-200/200/50 | 10kW | 50kV/1A four units (dry-type) |
10kVA (dry-type) |
200kV | 110kV power transformers of 50000kVA and below 110kV GIS, PT, CT, etc. (preventive test) 35kV (300mm2) cables ≤1.0km 10kV (300mm2) cables ≤2.0km |
| BPXZ-270/270/45 | 15kW | 45kV/1A six units (dry-type) |
15kVA (dry-type) |
300kV | 110kV power transformers of 50000kVA and below 110kV GIS, PT, CT, etc. 35kV (300mm2) cables ≤1.2km 10kV (300mm2) cables ≤3.0km |
| BPXZ-800/400/50 | 30kW | 50kV/2A eight units (dry-type) 100kV/2A four units (oil-immersed) |
30kVA (dry-type) 30kVA (oil-immersed) |
400kV | 220kV power transformers of 80000kVA and below 110kV power transformers of 50000kVA and below 110kV/220kV GIS, PT, CT, etc. 35kV (300mm2) cables ≤2.0km 110kV (300mm2) cables ≤0.7km |
| BPXZ-1600/800/200 | 60kW | 200kV/2A four units (oil-immersed) |
60kVA (dry-type) |
800kV | 220kV power transformers of 80000kVA and below 110kV power transformers of 50000kVA and below 500kV GIS, PT, CT, etc. 220kV switches, GIS, PT, CT, etc. 110kV (400mm2) cables ≤1.5km 220kV (400mm2) cables ≤1.0km |